Updated: Reliability Issues? How ’bout this?

The push is on to get a Cerificate of Public Good from the Public Service Board before there is a ruling on the appeal of Vermont Yankee/Entergy vs. the State of Vermont, and, in the interim, to block the PSB from acting to close the plant on schedule.   Entergy’s pulling out all the stops to court flagging public support for continued operation.

I don’t know if other local papers carried it, but last night the Messenger boasted a full-page ad from Vermont Yankee telling us why, on the one-year anniversary of the Fukushima nuclear disaster,  we shouldn’t give the safety of VY another thought because they are on the case!

Was this deliberately timed to distract the public from that elephant in the corner, the plant’s poor prognosis for reliability, so that the conversation visibly revolves around an issue over which the State has no jurisdiction? Maybe that’s giving them more credit than they are due.

In any case, as Stardust alerted us several days ago, that old black magic “reliability” recently reared its ugly head again when a system failure forced a down-scaling of service.

Now that we have a better idea of what was involved, we thought it was time to revisit the incident on GMD’s front page.  VTdigger yesterday reported on the technical issue, involving a key component, that forced Vermont Yankee to begin operating at reduced capacity.  Explaining that the role of the condenser is to act somewhat like a radiator, Digger reports that its functionality was compromised in the following way:

Last November, during a planned refueling outage, plant workers applied a protective coating – an epoxy or plastic – to the tubing in the condenser… At the beginning of February, nuclear engineers at the plant discovered that the the thermal heat exchange efficiency of the condenser was greatly reduced. Last week, the plant had to lower its power production by 50 percent because back pressure was building up in the condenser.

Apparently, the coating applied to extend the life of the condenser, which dates to the plant’s start-up 40 years ago, compromised the “efficiency” of the system.  In this case “efficiency” refers to its ability to operate without a pressure build-up.

…And in the very competitive category of “I Told You So,” the winner is…Arnie Gundersen.  

When asked in his 2003 testimony to the Public Service Board to name

a component likely to have an adverse effect on reliability under extended power uprate conditions

Mr. Gundersen responded that the condenser was likely to present exactly the scenario of improper repair and subsequent failure that has now occurred.

Gundersen, of Fairewinds Associates, now predicts that this thermal issue is likely to worsen in summer:

when the water temperature of the Connecticut River rises from springtime temperatures of 50 degrees to 70 degrees.

The upshot is that further power reductions will be likely so long as the plant continues to operate with the affected condenser in the system.

Sounds like a reliability issue to me.

On a different front, Vermont Senator Bernie Sanders is challenging the NRC to explain how they could go ahead and extend the Vermont Yankee operating license within just days of the unprecedented disaster at Fukushima which involved reactors of exactly the same generation as the one at Vermont Yankee.

Sanders, who, a year ago called for a moratorium on relicensing aging nuclear power plants in the U.S. until there had been an opportunity to draw lessons from the Fukushima chain of collapse, today chastised the agency for its unwillingness to alter its relicensing initiatives, and the federal government as a whole for policy that heavily subsidizes the nuclear industry and does not respect the right of a state like Vermont to phase out aging nuclear facilities in favor of sustainable energy built on other platforms.

“In my state there is a strong feeling that we want to go forward with energy efficiency and sustainable energy. I believe that we have that right. I believe that every other state in the country has that right,” Sanders said. “If we want to move to sustainable energy and not maintain an aging, trouble-plagued nuclear power plant, I think we should be allowed to do that.”

About Sue Prent

Artist/Writer/Activist living in St. Albans, Vermont with my husband since 1983. I was born in Chicago; moved to Montreal in 1969; lived there and in Berlin, W. Germany until we finally settled in St. Albans.

41 thoughts on “Updated: Reliability Issues? How ’bout this?

  1. First they pay workers to put the coating on… now they’ll pay ’em again to scrape it off.

    Just think of all the future employment we’ll lose if they shut VY down. Plumbers, carpenters, air testers, water testers, firefighting teams, containment crews. Hell, they’ll probably bring in some rodeo clowns.

    (No, actually, the clowns are already there. In the front office.)

    And imagine all the ancillary jobs from those urgent trips to Home Depot. The duct tape and spackle sales alone will bring an estimated $2 million a year to the local economy.  

  2. Wasn’t it just a couple years ago that Entergy decided that it would be better to place the $100M they had lying around the office into the CEO’s offshore account rather than waste it on a new condenser for VY?

    Why blow a $100M on an exhausted plant that you ‘intend’ to run for another 20 years at 120% capacity when the 40 year old condenser is working perfectly?  Especially when the CEO needs a third solid-gold house!

    That right there is my proof that they intend to run the place (and the rest of their decrepit money-pits) into the ground and then dissolve the LLC and abandon the tons of high-level nuclear waste to the people.

    If Entergy had been sparing no expense to perform a major overhaul to all the critical parts, I’d be less concerned, but now that the chewing gum they stuck in all the condenser’s cracks is getting stuck in the drain, I ask again: “Can we shut it down – yet?”  What more warning does Entergy need?

  3. Why does Entergy scrimp and save so aggressively on VY?

    The Rutland Herald reports the cost of replacing the condenser is estimated at about $150 million.

    According to Forbes J.Wayne Leonard head of Entergy Vermont Yankee’s owner earned in 2010 more than enough to pay for a new condenser out of his own pocket and have some left over for “groceries”

    Leonard was paid a salary of $1.34 million with a performance bonus of $1.78 million stock options and other compensation bring his total to package to $27.32 million



    http://www.forbes.com/lists/20

  4. touches upon some of the issues you presented here & raises new ones:

    The beginning of the end?

    03/16/2012

    “Earlier this week, the Nuclear Regulatory Commission released orders reflecting concerns that were raised following the nuclear disaster in Fukushima.

    Though the orders were applicable to all of the nation’s 104 operating reactors, they were especially important for plants such as Vermont Yankee in Vernon.”

Comments are closed.